Drying & Torrefaction

Drying & Torrefaction to produce 10 Tons per Hour of Torrefied Wood (TW) 

Superheated Steam Drying at Atmospheric Pressure 
Green Wood Chips                     50,000 lbs per hour
Moisture Content  50% MC
Water in Wood                     25,000 lbs/hr
Dry Wood                      25,000 lbs/hr
Moisture Content after Drying 8% MC
Wood for TW & Charcoal                     27,174 lbs/hr
Water Removed in Dryer                     22,826 lbs/hr
Heat Load for Drying                    1,500.85 Btu/lb water
Total Heat Load for Drying                         34.3 MMBtu/hr
Dryer Inlet Steam Temp                           428 F.
Dryer Inlet Steam Enthalpy                    1,253.18 Btu/lbm
Dryer Outlet Steam Temp                           302 F.
Outlet Steam Enthalpy                    1,193.56 Btu/lbm
Change in Enthalpy                       59.62 Btu/lbm
Steam Recirculated                    574,581 lbm/hr
Steam Vented at 302 F.                     22,826 lbs/hr
Superheated Steam Torrefaction  
Wood for Torrefaction                      27,174 lbs/hr
Water in Wood                        2,174 lbs/hr
Water Enthalpy at 90 C. (194 F.)                          162 Btu/lbm
Steam Enthalpy at 280 C. (536 F.)                       1,305 Btu/lbm
Difference                       1,142 Btu/lbm
Heat to Dry Wood to 0% MC                         2.48 MMBtu/hr
Bone Dry Wood                      25,000 lbm/hr
Temperature of Wood into Torrefaction (110 C.)                          230 F.
Torrefaction Temperature (280 C.)                          536 F.
Temperature Difference                          306 deg. F.
Specific Heat Capacity of Bone Dry Wood                         0.30 Btu/lbm-deg F.
Heat Input to Torrefy Dry Wood                         2.30 MMBtu/hr
Incl 20% for Structural Losses                         2.87 MMBtu/hr
Indirect Heater Load for Torrefaction                         2.87 MMBtu/hr
Torrefaction Steam at 280 C. (536 F.)                       2,199 lbs/hr
Summary
Yield of TW 

80%

TW                      20,000 lbs/hr
Heating Value                        8,500 Btu/lb
Heat Load for Drying                       34.26 MMBtu/hr
Heat Load for Torrefaction                         2.87 MMBtu/hr
Total Heat Load                        37.13 MMBtu/hr
Calculation of Heat Input to Dryer
Heat 1 lb of moisture from 68 F. to 212 F.                          144 Btu/lbm water
Heat 1 lb of dry wood from 68 F to 212 F  Cp = 0.3 43.2 Btu/lbm dry wood
Evaporate 1 lb water at 100 C. 970.4 Btu/lbm water
Superheat 1 lb of vented steam from 212 to 302 F.                       43.08 Btu/lbm steam
Moisture Content of Feed  50%
Heat Water                       72.00
Heat Wood                       21.60
Evaporate. Water                     485.20
Superheat Steam                       21.54
                    600.34 Btu/lb of wet Wood
1200.68 Btu/lbm water
Incl. 20% for Structural Losses 1500.85 Btu/lbm water

Two Stage Drying to Remove Free & Bound Water

Superheated Steam Drying at Atmospheric Pressure 

Remove Free Water 

Remove Bound Water

Wood for TW          50,000 lbs per hour          35,714 lbs per hour
Moisture Content  50% MC 30% MC
Water in Wood          25,000 lbs/hr          10,714 lbs/hr
Dry Wood           25,000 lbs/hr          25,000 lbs/hr
Moisture Content after Drying 30% MC 8% MC
Wood Out of Dryer          35,714 lbs/hr          27,174 lbs/hr
Water Removed in Dryer          14,286 lbs/hr            8,540 lbs/hr
Heat Load for Drying        1,575.38 Btu/lb water       1,266.85 Btu/lb water
Total Heat Load for Drying              22.5 MMBtu/hr              10.8 MMBtu/hr
Dryer Inlet Steam Temp                750 F.               428 F.
Dryer Inlet Steam Enthalpy        1,408.38 Btu/lbm       1,253.18 Btu/lbm
Dryer Outlet Steam Temp                428 F.               302 F.
Outlet Steam Enthalpy        1,253.18 Btu/lbm       1,193.56 Btu/lbm
Change in Enthalpy          155.20 Btu/lbm            59.62 Btu/lbm
Steam Into Dryer         145,009 lbm/hr        181,462 lbm/hr
Steam Out of Dryer        159,295 lbs/hr        190,002 lbs/hr
Outlet Steam Enthalpy        1,253.18 Btu/lbm
           199.6 MMBtu/hr
Steam Vented           22,826 lbs/hr
Calculation of Heat Input to Dryer
Temperature of Wood Chips into Dryer                68 F.               300 F.
Heat 1 lb of moisture from 68 F. to 212 F.               144 Btu/lbm water 0 Btu/lbm water
Heat 1 lb of dry wood from 68 F to 212 F  Cp = 0.3 43.2 Btu/lbm dry wood 0 Btu/lbm dry wood
Evaporate 1 lb water at 100 C. 970.4 Btu/lbm water 970.4 Btu/lbm water
Superheat 1 lb of vented steam to outlet temp.          102.71 Btu/lbm @ 428 F            43.08 Btu/lbm @ 302 F.
Moisture Content of Feed  50% 30%
Heat Water            72.00                 -  
Heat Wood            21.60                 -  
Evaporate. Water          485.20          291.12
Superheat Steam            51.35            12.92
         630.15 Btu/lb of wet Wood          304.04 Btu/lb of wet Wood
1260.31 Btu/lb water 1013.48 Btu/lb water
Incl. 20% for Structural Losses 1575.38 Btu/lb water 1266.85 Btu/lb water

Up Heat Recovery TW & Biochar